BB-18 Biomass Furnace

Biomass FurnaceBB-18 Non-auto Ash DischargeBB-18 Auto Ash Discharge
Biomass FuelPressed straw bricks,
corn cob, coconut shell, wood chip
Paddy husk, coffee hullPaddy husk
Dimension(mm)3521×2048×48853521×2795×6002
Net weight(kg)34204150
Max.Thermal Energy(kcal/hr)180,000 (approx.)
Husk Consumption(kg/hr)12~76 Under max. combustion(approx.)
Ash discharge(kg/hr)2.4~15.12 Under max. combustion(approx.)
Consumption of
Pressed straw bricks(kg/hr)
67 Under max. combustion(approx.)
Wood Consumption(kg/hr)10~70(approx)
Annual diesel saving (Approx.)60,000 liter/120days / 136,000 liter/270days
Automatic ash discharge system
(Optional,for husk)kW(HP)
0.2 (0.25)
Husk feeder
(Optional,for husk and coffee hull) kW(HP)
0.6 (0.8)0.6 (0.8)
Power Consumption kW(HP)4.5(6)5.1 (6.8)5.3 (7)
Safety DevicesThermo relay, Overheat sensor, Control FuseThermo relay, overheat sensor, control fuse
ModelSUPER-120BSUPER-300-240B

SUPER-300B

MD-165BCPR-165B
Capacity
(kg)
Paddy 1liter=560g2800~120004000~240004000~300005700~132006500~13250
wheat 1liter=680g3400~145505000~291005000~364006900~162007500~16350
Corn 1liter=690g3450~147607500~16350
DimensionOverall Length (mm)4089499958325565
Overall Width (mm)2660378627832675
Overall Height (mm)96021040711629102729671
Net weight Approx. kg24604900520033983420
Power Consumption kW(HP)7.75(10.33)16.75(22.6)14.75(19.7)7.7(10.3)
Electricity3 Phase, 220V/380V/415V/440V, 50Hz/60Hz
Temp. range Ambient temp.
(For single unit)(Paddy)
+10~54℃+10~28℃+10~32℃+10~50℃
Function
(Paddy)
(approx)
Loading (min)6058656672
Discharging (min)5858706566
Drying Rate(% / hr )0.5~1.50.5~1.00.4~0.70.7~1.20.5~1.2
Safety devicesThermo-over relay, air pressure switch, full load buzzer, timer, control fuse.
 

※Specifications subject to change without notice.
※The specification and graph is for reference only.
  Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
※SUPER-300-240B, SUPER-300B, MD-165B is applied for drying paddy and wheat seed only
※Max. thermal energy, husk consumption and exhausted ash production listed are for reference only.
  Actual data will differ upon variety, moisture content and impurity
※Conditions of pressed straw bricks:
  1.Moisture content: less than 13%.
  2.Thermal energy: 3,700~4,200 Kcal/kg.
  3.Dust content: as low as possible
※Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15% ─ for reference only.
  Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature,
  moisture content before and after drying.